M210
These Stratum 1 modular time and frequency master clock systems are an advanced, high precision timing platform commonly specified for use in critical timing applications that depend upon a reliable, quality time standard. The M210 unit is 1U platform with 3 expansion slots while the M211 is a 3U platform with 9 expansion slots.
With a range of over 40 functional module blocks, each system can be optimised to suit specific application demands spanning multi format I/O networks, NTP Time servers, time code readers and generators, multi-
The robust design and unrivalled build quality delivers exceptional performance and trouble free product field longevity.
Software interfaces such as those available on the 3 port NTP time server module are proven and hardened against common cyber attack methods.
No matching variations found.
M212 Balanced Binary Coded Decimal Time Code Output (J Designator)
Model #M212-BAL-BCD-J
DownloadSpec Sheet
Variations
Description | Model Number | Product Type | Oscillator Type | Power Supply | Form Factor | Power Type | Output Format | Input Format |
---|---|---|---|---|---|---|---|---|
M212 1U Base Unit | M212 | M212 Base Unit | 90-265 VAC | 1U | AC | Power | ||
M212 1U Base Unit - 24 VDC Power Option | M212-24VDC | M212 Base Unit | 24 VDC | 1U | DC | Power | ||
M212 1U Base Unit - 48 VDC Power Option | M212-48VDC | M212 Base Unit | 48 VDC | 1U | DC | Power | ||
M212M 1U Base Unit | M212M | M212 Base Unit | 90-265 VAC | 1U | AC | Power | ||
M212M 1U Base Unit - 24 VDC Power Option | M212M-24VDC | M212 Base Unit | 24 VDC | 1U | DC | Power | ||
M212M 1U Base Unit - 48 VDC Power Option | M212M-48VDC | M212 Base Unit | 48 VDC | 1U | DC | Power | ||
M212 1U Base Unit (SAASM Version) | M212-SAASM | M212 Base Unit | 90-265 VAC | 1U | AC | Power | ||
M212 Master Clock Module | M212-MCM | Master Clock Module | TCXO | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GNSS, Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 OCXO Oscillator Option | M212-OCXO | Master Clock Module | OCXO | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GNSS, Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 Rubidium Oscillator Option (J Designator) | M212-RB-J | Master Clock Module | Rubidium | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GNSS, Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 CSAC Oscillator Option (J Designator) | M212-CSAC-J | Master Clock Module | CSAC | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GNSS, Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 High Performance Rubidium Oscillator Option | M212-HP-RB | Master Clock Module | Rubidium | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GNSS, Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 Master Clock Module (SAASM Version) | M212-MCM-SAASM | Master Clock Module | TCXO | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GPS (SAASM), Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 Rubidium Oscillator Option - TTL Interface | M212-RB-TTL | Master Clock Module | Rubidium | 1x M212 Module | Have Quick, IRIG B DCLS + IEEE1344 CF, 10 MHz | GPS, GNSS, Have Quick + 1PPS, IRIG B, IRIG B + 1PPS | ||
M212 2X BNC/TRIAD Universal Output Signal Module | M212-UNIV-2X-TRI | Output Signal Module | 1x M212 Module | 1PPS, 1PPM, Have Quick, IRIG A, IRIG B, IRIG E, IRIG G, IRIG H, XR3, 2137 | ||||
M212 4X TRIAD Universal Output Signal Module | M212-UNIV-4X-TRI | Output Signal Module | 1x M212 Module | 1PPS, 1PPM, Have Quick, IRIG A, IRIG B, IRIG E, IRIG G, IRIG H, XR3, 2137 | ||||
M212 4X BNC, Universal Output Signal Module | M212-UNIV-4X-BNC | Output Signal Module | 1x M212 Module | 1PPS, 1PPM, Have Quick, IRIG A, IRIG B, IRIG E, IRIG G, IRIG H, XR3, 2137 | ||||
M212 NTP Server Output Signal Module | M212-NTP | Output Signal Module | 1x M212 Module | NTP | ||||
M212 8-PORT RS232/RS422 Output Signal Module | M212-RS232-RS422 | Output Signal Module | 1x M212 Module | RS232, RS422 | ||||
M212 PTP Grandmaster Output Signal Module | M212-PTP | Output Signal Module | 1x M212 Module | PTP | ||||
M212 E1/T1 Output Signal Module | M212-E1T1 | Output Signal Module | 1x M212 Module | E1, T1 | ||||
M212 1PPS Output Signal Module (J Designator) | M212-1PPS-J | Output Signal Module | 1x M212 Module | 1PPS | ||||
M212 5MHz Output Signal Module (J Designator) | M212-5M-J | Output Signal Module | 1x M212 Module | 5 MHz | ||||
M212 10MHz Output Signal Module (J Designator) | M212-10M-J | Output Signal Module | 1x M212 Module | 10 MHz | ||||
M212 Balanced Binary Coded Decimal Time Code Output (J Designator) | M212-BAL-BCD-J | Output Signal Module | 1x M212 Module | BCD | ||||
M212 Modulated Time Code Output (J Designator) | M212-TC-J | Output Signal Module | 1x M212 Module | Have Quick, IRIG A, IRIG B, IRIG E, IRIG G, IRIG H, XR3, 2137 | ||||
M212 Have Quick Time Code Output Signal Module (J Designator) | M212-HQ-TC-J | Output Signal Module | 1x M212 Module | Have Quick | ||||
M212 Extended Performance PTP Grandmaster Output Signal Module | M212-EP-PTP | Output Signal Module | 1x M212 Module | PTP | ||||
M212 Optical Crosslink Module | M212-OPT | Output Signal Module | 1x M212 Module | Fiber Optic | Fiber Optic | |||
M212 RS422 Output Signal Module (J Designator) | M212-RS422-J | Output Signal Module | 1x M212 Module | RS422 | ||||
M212 10MHz Low Phase Noise Output Signal Module | M212-LPN10 | Output Signal Module | 1x M212 Module | 10 MHz | ||||
M212 5 MHz Low Phase Noise Output Signal Module | M212-LPN5 | Output Signal Module | 1x M212 Module | 5 MHz |
Features
Features:
- Module Expansion Slots: M210 – 3 Slots
- Disciplined Oscillators: Choice of TCXO, OCXO and high performance Rubidium atomic clock
- Power Supplies: Single or Twin Universal AC mains or 48 V DC or combination as required
- Time Sync Sources: GPS, MSF, DCF, 1PPS, IRIG-B, IRIG-E, 2137, XR3, AFNOR, Mains AC, NTP
- Module Output Formats: NTP, RS422, RS232, 1PPS, AFNOR, 1MHz, 5MHz, 10MHz, E1/T1 Telecoms, HQ, IRIG-B, SMPTE-EBU, Audio, Video Overlay, 4-20mA, Clock Impulse, Volt free relay
- Approvals: Qualified for use in ATC, Public Transport, Network Rail, Oil & Gas – CE, ISO9001, AS9100D
- Remote interfaces: Web browser based Clock Management System (CMS), configuration tools and Virtual Machine Interface
- Warranty: 3 Years standard – Options for extended warranty and support contracts
Typical Applications
M210 & M211 are common place and thoroughly proven worldwide in safety critical applications such as Air Traffic Control, Rail & Road Networks, Oil & Gas installations and some military applications.
The units are built to AS9100D design and manufacturing standards and are factory configured on a per order basis.
The platform and many of the associated modules have been type approved for ATC & rail networks, backup by impressive MTBF performance figures.
Dual redundant Master Clock Systems may be implemented by the inclusion of an M842 switchover unit.