Time and Frequency Solutions
 

FTM8000 Frequency Monitor

The FTM8000 Frequency Monitor allows local and remote high-resolution monitoring of up to seven standard frequency inputs against a reference frequency input.

Features

  • Up to seven 5MHz or 1MHz inputs available
  • Phase measurement down to 250ps
  • Frequency measurement down to 2.5x10-10
  • Hardware status port & front panel error indicators
  • Comprehensive alarm outputs
The monitor indicates the status of the connected frequencies and the selected reference on its front panel. A hardware status port is also provided. Relative phase and fractional frequency difference measurements of each input compared to the reference input are reported at a selectable time interval through an RS232 or RS422 serial port connection.

The user can select which fields are to be included in the output message by means of a simple command. Similarly, unused inputs can be designated as not in use to eliminate status error reports and unwanted measurements.

The monitor allows problem frequency sources to be identified rapidly and designated for de-selection if required. The standard frequencies are 10MHz sine-wave sources but the unit can be factory reconfigured to accept 5MHz or 1MHz inputs. The instrument can be supplied with 50-ohm or 75-ohm input connectors.


Specifications

Interface:  9-way D-type Serial Interface (RS232) 15-way  D-type
Frequency Status:  Output 5-way Alarms Output 8* 50ohm BNC Input  Jacks Mains and DC Connector
Standard Serial Interface:  9600 baud, 8 data bits, no parity, 1 stop bit, no  flow control
Interface Type: RS232 or RS422 by internal jumper selection
Frequency Input Nominal: 1Vrms (+13dBm) sinewave or squarewave 
Minimum: 0.22Vrms (0dBm)
Data Output Frequency:    1/s. 10/s, 100/s, or 1000/s
Termination:   50-ohm or 75-ohm jumper selectable internally  (Note: not fitted at factory)
Phase Resolution: 250ps
Phase Range : ±0.53seconds (internal 32 bit count of 250ps   units)
Frequency Difference Resolution: ±2.5E-10 in 1 second from 0 to ±100ppm
Frequency Difference Range: ±100ppm
AC Power Supply: 85-264 Vrms @47-63Hz 12VA Typical
AC Power Fuse: T1A Slow-blow 20mm Glass
DC Power Supply: 24V nominal (19-36V) @300mA (400-200mA) Typical, 24mA Standby
DC Power Fuse: T1.25A 20mm PCB Mounted
Mechanical: 19" 1U rack mounting, 305 mm deep
Weight: 2kg
Temperature (Operation):  -10oC to +50oC
Humidity: Up to 95% RH (non-condensing)
EMC: CE Compliant


enlarge imageFTM8000 Frequency Monitor



Download product datasheet

Tel: +44(0)1376 514114 Email: enquiries@timefreq.com