Time and Frequency Solutions
 

TFD8000 Time & Frequency Distribution System


The TFD8000 Time & Frequency Distribution System is a powerful and versatile distribution system designed for applications where a wide variety of high precision analogue and digital time and frequency signals are required. It is suitable for a wide range of high-end industrial and military applications.


Features

  • Available in a range of chassis configurations (19 inch rack-mountable)
  • Proprietary Backplane system allows the generation of any frequency, pulse rate or timecode from just three core signals.
  • Dual or triple redundancy simply achieved within the instrument
  • Internal or external time signal source
  • Option to lock oscillator to source or allow free run source
  • Fulfils complex system requirements
  • Wide range of option modules

Chassis Configuration Options
  • Single Depth - 20 module slots
  • Dual Depth - 34 module slots
  • Dual Pack - Additional chassis available for housing redundant Tracking
  • Oscillator/Clock modules.

Through the use of separate earth planes for digital and analogue signals, high-speed digital pulse rates and timecodes are available together with low phase noise frequencies in a single instrument.

The proprietary backplane system allows the generation of any frequency, pulse rate or timecode from just three core signals. This ensures that advanced features such as dual or triple redundancy can be simply achieved within the instrument thus improving the overall availability of the system.

The TFD8000 can be configured to process and distribute time and frequency signals referenced to an external source such as an external GPS Receiver or Cesium clock.

Alternatively, the TFD8000 can generate the signals internally by means of an integral GPS or LF Receiver. Additionally, a wide variety of oscillators is available for inclusion in the Tracking Oscillator/Clock module, which can be configured either to free run or to lock to the reference source. By selection of the appropriate oscillator, the required holdover performance can be met in a cost effective manner.

For the most complex applications including full redundancy, a complete TFD8000 System may comprise of a number of chassis in combination, thereby fulfilling complicated system requirements that are far beyond the capacity of most competitive products. Most distribution modules are 4E wide and provide 5 outputs of a particular signal type.

A wide range of option modules is available for use with the TFD8000 System. Full details are available on each of the various options.

Specifications

Mechanical
A number of chassis configurations are available for the TFD8000. These include the Single Depth, Dual Depth, and Dual Pack chassis. In all cases, these chassis are 19-inch rack mountable and are of ruggedised military grade. Full mechanical details of the available chassis are included in the relevant Product Literature.

Synchronisation Sources
The following synchronisation sources can be selected for the equipment

  • Global Positioning System - GPS (external or integral)
  • Cesium (external or integral)
  • LF Radio Transmission (WWVB, MSF, DCF77)
  • Timecode (IRIG-B, IRIG-E, XR3, 2137, AFNOR)
  • Havequick (I, II, IIa, Saturn)

Holdover Performance
The holdover performance of the TFD8000 System is dependant on the internal oscillator(s) selected for the application. Full details of available oscillators are contained in the Tracking Oscillator/Clock module Product Literature.

Signal Output
A wide range of signal and frequency output modules are available. Full details are contained in the relevant Product Literature.

Power
The TFD8000 System can be configured to operate from the following power sources: 115/230V AC; 24V DC; 48V DC. Additionally, the system may also contain an integral Standby Supply.

Environmental
Temperature (Operating): 0°C to +50°C
Temperature (Storage): ?40°C to +70°C
Humidity: MIL-STD-810E Procedure 507.3
Salt Fog: MIL-STD-810E Procedure 509.3
Altitude: MIL-STD-810E Procedure 500.3
Vibration: MIL-STD-167-1
Shock : MIL-S-901-C
EM: MIL-STD-461 CE01, CE102, CS101, RS101, RE101, CS114 (10kHz-30MHz), RE102 (10kHz-1GHz), RS103 (2MHz-19GHz)
ESD: IEC801-2

tfd8000
tfd8000 rear

Click on an image to enlarge

Download TFD8000 datasheet

Download TFD8000 Applications Brochure

Tel: +44(0)1376 514114 Email: enquiries@timefreq.com
Website Design: Tristar Web Solutions